Envelopes fail at transitions: window frames, floor lines, penetrations. Thermal assessment shows where heat and air take the shortcuts, and where moisture hides behind finishes.

Symptoms we're called for

  • Cold rooms, drafts and condensation on interior surfaces
  • Mould at wall bases or window frames
  • Energy use higher than neighbours in similar units
  • A building science review needed before renovation

Property types

  • Homes and condos
  • Strata buildings and townhouse complexes
  • Commercial facades and curtain walls

Methods used

  • Depressurization-assisted infrared scanning where appropriate
  • Thermal review of transitions, frames and penetrations
  • Moisture readings to separate wet from merely cold
  • Comparative scans after air sealing or repair

Limitations, stated plainly

  • Assessments identify performance issues, not code compliance
  • Wind, sun and interior heating affect readings
  • Concealed damage may need invasive confirmation by others

What you receive

  • Annotated thermal set by elevation or room
  • A findings map of insulation gaps, leaks and moisture
  • Prioritized recommendations

Next steps

  • Air-seal or insulate where gaps are confirmed
  • Dry and verify areas with moisture
  • Re-scan after work to confirm improvement